질문 # 114
What is a potential disadvantage of using a hypoxic-based fire suppression system as a fire extinguishing system?
정답:C
설명:
A hypoxic-based fire suppression system works by reducing the oxygen level in a room to below what is necessary to sustain combustion. This makes it effective in fire prevention, but it is not suitable for continuous occupancy by personnel. Low oxygen levels can cause discomfort or even health risks for people spending extended periods in the space. Therefore, these systems are typically deployed in areas where continuous human occupancy is not required, such as storage rooms or data halls with limited personnel access.
Detailed Explanation:
Hypoxic fire suppression systems lower oxygen levels to around 15-16%, which is safe for short periods but not sustainable for continuous occupancy without risk to health. Data center environments where staff need to spend long periods monitoring and maintaining equipment would need alternative systems, like gas-based suppression that allows for safe evacuation rather than oxygen reduction.
EPI Data Center Specialist References:
The EPI Data Center Specialist curriculum emphasizes that fire suppression systems must be chosen based on occupancy requirements. Hypoxic systems are specifically noted as unsuitable for spaces requiring continuous human presence due to the low oxygen environment they create.
질문 # 115
The building requires sprinklers and is equipped with a wet-pipe system. What action should you recommend for the computer room?
정답:B
설명:
NFPA 75 (IT equipment rooms) recommends pre-action sprinklers for data processing spaces to minimize accidental water discharge risk; wet-pipe is generally discouraged directly over IT hardware.
References: NFPA 75 §5.4 (Water-based fire protection), NFPA 13 (sprinkler system types).
질문 # 116
The humidity in the computer room has increased from about 60% up to 85% Relative Humidity (RH). What potential risk does this pose to your equipment?
정답:B
설명:
High relative humidity (above 80%) creates a serious risk for corrosion of electronic contacts, printed circuit boards (PCBs), and metallic components. Moisture in the air condenses more easily, especially when surfaces are cooler than ambient dew point. This can lead to oxidation of connectors, degradation of solder joints, and eventual failures in ICT hardware.
Electrostatic discharge (ESD) risks, by contrast, increase at low humidity (below 30%) because dry air promotes charge buildup. Therefore, option C is incorrect here. Similarly, option D (cooling risk from wet- bulb temperature) applies to evaporative cooling efficiency, not directly to ICT risk.
ASHRAE recommends data centers maintain RH between 40-60% for optimal reliability. Values above 80% RH are considered outside the recommended operating envelope and significantly increase the risk of corrosion, especially in the presence of airborne contaminants like sulfur dioxide (SO#) or hydrogen sulfide (H#S).
Therefore, the verified risk at 85% RH is corrosion-related degradation.
References: ASHRAE TC 9.9 Thermal Guidelines (2016 Edition, Table 4.1), IEC 60721-3-3 Environmental Conditions for ICT Equipment.
질문 # 117
What is the main reason to install Earth Leakage protection?
정답:C
설명:
Earth Leakage Protection is primarily installed to protect human lives by detecting and disconnecting power when a fault current flows to the ground. This type of protection is essential to avoid electrical shock hazards that could occur when insulation fails, or equipment is improperly grounded.
Detailed Explanation:
Earth leakage currents can occur due to insulation faults or accidental contact with live parts. Earth Leakage Protection systems, such as Residual Current Devices (RCDs), quickly detect these faults and disconnect the circuit to prevent harm to personnel. This is especially crucial in environments like data centers where high-powered equipment is continuously running and any electrical fault can pose significant safety risks.
EPI Data Center Specialist References:
EPI emphasizes that human safety is paramount in data center operations. Proper grounding and leakage protection are fundamental safety measures, and EPI guidelines align with this focus, underscoring the importance of protecting personnel from electrical hazards through appropriate safety systems.
질문 # 118
Is it allowed to make design changes during the implementation phase?
정답:C
설명:
Design changes during the implementation phase are generally allowed only when there is a strong business and/or technical justification. Changes at this stage can lead to delays, increased costs, or compromise design integrity. Thus, a rigorous assessment is required to ensure any modifications are essential and provide clear benefits or address critical issues.
Detailed Explanation:
Changes post-design freeze should be minimized to avoid scope creep and additional costs. However, if a technical issue arises that would affect operational goals, or a business need warrants modification, justified changes are permissible, following an impact assessment and approval process.
EPI Data Center Specialist References:
EPI project management guidelines recommend a controlled change management process during implementation, allowing changes only when they align with critical objectives or address unforeseen issues that affect the project's success.
질문 # 119
......
Pass4Test의 EXIN인증 CDCS시험덤프는 고객님의 IT자격증을 취득하는 꿈을 실현시켜 드리는 시험패스의 지름길입니다. EXIN인증 CDCS덤프에는 실제시험문제의 거의 모든 문제를 적중하고 습니다. Pass4Test의 EXIN인증 CDCS덤프가 있으면 시험패스가 한결 간편해집니다.